FISHER DLC3100 displacer level transmitter
FISHER DLC3100 displacer level transmitter
Main technical parameter Power supply: 12~30V DC; the controller has reverse polarity protection.(when HART is communicating, the voltage of controller ≥17.75V DC) Output signal: 4~20 mA DC (Positive direction – the increase of level, interface, or density make output increase; Negative direction – the increase of level, interface, or density make output decrease.) Measuring range: 300mm—2500mm (can also over range) Nominal pressure: ≤42.0Mpa Nominal diameter: DN40 or as customers’ request Ambient temperature: –40ºC to +80ºC (when ≤–30ºC, no LCD display) Operating temperature: –70ºC to +400ºC Measuring accuracy: 0.5% Influence from power supply: When the voltage of the power supply varies between min. and max. ,the output change is within <±0.2%. of the full scale. LCD display: Output current signal、process variable、process temperature、percentage range、rotation angle of torque tube. Medium density difference: ≥0.08g/cm³ Material of torque tube: Standard configuration Inconel 600,or Monel, HasetlloyC-276 Wetted material: 304、316L or as customers’ request Flange standard: HG/T20592-2009、HG/T20615-2009 or as customers’ request Power entry: Two NPT 1/2 (female thread) or as customers’ request Explosion-proof: Explosion isolation ExdⅡCT6, Intrinsically safe ExiaⅡCT6 Protection grade: IP66 Alarm jumper: For the self-diagnosis to the inaccuracy failure of the process variables (for example, the electronic module failure). Configure the process variables of high and low alarms. Ambient temperature and Medium temperature limit WWW.DDTOP.COM 2WWW.DDTOP.COM 3 ZTD series Smart Displacer Level (Interface) Transmitter Model selection table Model Code Code meaning ZTD- DLC3000 Smart displacer transmitter 1 Level measurement 2 Interface measurement 3 Density measurement A Top-side mounted B Top-bottom mounted C Side-side mounted D Bottom-side mounted E Top mounted F Side mounted S Top-bottom S style mounted 1 Nominal pressure ≤PN2.5MPa, 2.0Mpa (Class 150) 2 Nominal pressure: PN4.0MPa 3 Nominal pressure: PN6.3MPa, 5.0MPa (Class 300) 4 Nominal pressure: PN10.0MPa, 11.0MPa (Class 600) 5 Nominal pressure: PN16.0MPa, 15.0MPa (Class 900) 6 Nominal pressure ≤PN26.0MPa (Class 1500) 7 Nominal pressure ≤PN42.0MPa (Class 2500) need to review / Intrinsically safe i Explosion protection: intrinsically safe d Explosion protection: explosion isolation T Chamber material : carbon steel H Chamber material: 304 (others as actual fill in) L Medium temperature: -70℃≤T<-30℃ D Medium temperature:-30℃≤T<+100℃ G Medium temperature: +100℃≤T≤+400℃ / Range According to actual fill in, unit is mm. F Chamber with heating, flange connection DN15, PN2.5 RF Additional code Z Chamber with heating, thread joint R1/2 W Left mounted transmitter (without “W” is right mounted transmitter) Example : 2C3/iTD/800F: smart displacer, measuring interface, side-side mounted, nominal pressure is PN6.3MPa or PN5.0MPa intrinsically safe, chamber material is carbon steel, medium temperature-30℃≤T< +100℃, measuring range is 800mm, chamber with heating, flange connection with heating tracing. 1. The structure and size H in following chart is measuring range, nominal pressure ≤6.3Mpa. Size in bracket is product with heat insulation sleeve. A: Top-side mounted version B: Top-bottom mounted version C: Side-side mounted version D: Bottom-side mounted version E: Top mounted version F: Side mounted version S: Top-bottom S style mounted version 5 2. Mounting orientation of the smart level controller Mount the controller on the chamber. When the controller is mounted on the right of the displacer chamber, the transmitter is called right-mounted, so when the level increases, torque tube turns in clockwise. When the controller is mounted on the left of the displacer chamber, the transmitter is called left-mounted, so whe